IP67 Speakers: What the Rating Does and Does Not Promise
Quick Summary
- The first digit is solids.
- A part rated IP67 and tested once at the factory has told you it was sealed the day it was made.
- Sealing a speaker means putting a membrane in front of the diaphragm, and every membrane costs output.
IP67 is a specific, narrow test. It says nothing about salt, steam, detergents or repeated cycling, and the sealing that earns the rating always costs you acoustic output. Specify accordingly.
Ingress protection ratings get quoted as though they were a general statement of ruggedness. They are not. IEC 60529 defines two digits and a small number of very specific tests, and everything outside those tests is unaddressed.
Reading the two digits
The first digit is solids. A 6 means dust-tight, tested for eight hours under partial vacuum. The second digit is liquids. A 7 means immersion in one metre of water for thirty minutes. That is the whole claim.
Note that the digits are not cumulative in the way people assume. IPX7 does not imply IPX5: a part that survives immersion may fail a directed jet, because the tests stress seals differently. If your product will be hosed down, ask for IP67 and IP65 together.
What IP67 does not cover
- Salt water, which attacks terminals and adhesives that fresh water leaves alone.
- Steam and pressure washing, which drive moisture past seals that hold against static immersion.
- Detergents and solvents, which degrade membranes and gaskets over time.
- Repeated thermal cycling, which is what actually opens most seals in the field.
- Any duration beyond thirty minutes, or any depth beyond one metre.
A part rated IP67 and tested once at the factory has told you it was sealed the day it was made. Whether it is sealed after two years on a food-processing line is a different question with a different test behind it.
The acoustic cost of sealing
Sealing a speaker means putting a membrane in front of the diaphragm, and every membrane costs output. Expect three to six decibels of loss, weighted towards the high frequencies, which is where speech intelligibility lives.
Budget the sealing loss at the start. Finding six missing decibels after the enclosure is tooled is an expensive discovery.
Membranes and vents
Two components do the work. The acoustic membrane passes sound and blocks liquid. The pressure vent equalises the sealed volume, so that a change in altitude or temperature does not push the diaphragm out of its linear range or, in the worst case, pop the seal.
A sealed speaker without a vent is a design that works on the bench and fails on an aircraft.
Specifying the test, not just the rating
Write the requirement as the condition the product will actually meet: the liquid, the temperature, the duration, the number of cycles, and the acoustic performance you still need afterwards. Then ask the supplier to test to that.
Most will, and the ones who will not have told you something useful.
Need help selecting a part?
Send us your requirements and we will suggest candidates from stock, with datasheets and samples.